品牌中杰特装
型号CFL-20/2.16
类型低温储罐
材质16MnDR
适用物料LCO2
液体的排放 liquid discharge
【产品详情图片】
2.4.1液体二氧化碳的正常排放是在储罐增压后,开启V2排液阀,V3回气阀,液体二氧化碳便流入汽化器汽化,供使用点使用。
The normal discharge of liquid carbon dioxide is after pressurization of the tank, open the V2 drain valve, V3 return valve, the liquid carbon dioxide will flow into the vaporizer vaporization for use point.
2.4.2为满足排液过程的稳定压力,应按“储罐的增压”操作方法进行增压。
In order to meet the steady pressure of the drainage process, it should be pressurized according to the method of "pressurized tank".
【产品详情图片】
【标题】
液体的储存 liquid storage
液体二氧化碳的储存属于带压(压力不低于0.8Mpa)储存。储存期间除压力表、液位计、安全阀应投入使用外,其他阀门应处于关闭状态。当储罐压力超过2.1Mpa时,开启V7排气阀降压。但应注意:内罐的压力不得降至低于0.8Mpa,否则将引起液体二氧化碳转变为干冰。
Liquid carbon dioxide storage with pressure (pressure not less than 0.8Mpa) storage. During the storage, the pressure gauge,level gauge, safety valve should be put into use, the other valves should be closed. When the tank pressure exceeds 2.1Mpa, open the V7 exhaust valve buck. However, it should be noted that the pressure inside the tank must not drop below 0.8Mpa, otherwise liquid carbon dioxide will be converted to dry ice.
【产品详情图片】
【标题】
【标题】
【变量2】【变量1】
【产品详情图片】
山东中杰特种装备股份有限公司是国内知名的低温储罐生产厂家,具有A1,A2压力容器设计、制造许可证,专业从事液氧LO2、液氮LN2、液氩LAr、液态LCO2及液化天燃气(LNG)等低温液体贮罐、大型常压贮罐和Ⅰ、Ⅱ、Ⅲ类非标压力容器设备、化工设备,产品广泛用于制药、石油化工、有机合成、冶金、食品、医疗、生物工程、国防等行业。三十几年来,企业规模不断发展壮大,现拥有固定资产3.5亿元,生产厂区3个,具有先进的加工设备和完善的检测设备,公司现有职工800余人,年销售4亿多元,并把低温压力储罐作为公司爆品打造。
【产品详情图片】
常见故障的处理 Common fault handling
【产品详情图片】
1.内罐压力异常长高 Inner tank pressure abnormally high
1.1可能是V3回气阀开度过大或阀门失灵,应减小阀门开度或检修阀门。
May be V3 return valve opening is too large or valve failure, should reduce the valve opening or valve repair.
1.2可能是S1、S2安全阀失灵,到启动压力不启动,应检查安全阀。
may be S1, S2 safety valve failure, to start the pressure does not start, check the safety valve.
1.3可能是压力表指示不准确,应校验压力表。
may be pressure gauge indicates inaccurate, should verify the pressure gauge.
2.液位计指示不真实 Level gauge instructions are not true
2.1可能是液位计失灵,应检修液位计。
may be the level gauge failure, should be maintenance level gauge
2.2可能是液位计接头处泄漏,应检修接头连接处,排除泄漏。
It may be a leak at the head of the liquid level gauge. It should repair the connection of the joint and eliminate the leakage
3.蒸发率高,外壳体凝水结霜 High evaporation rate, the outer shell condensate frost
3.1可能是珠光砂未填实或下沉,应补充珠光砂,重新抽真空。
may be unfilled or sinking of pearl sand, pearl sand should be added and re-evacuated.
3.2可能是真空度恶化,应进行真空检漏,重新抽真空。
may be a deterioration of the vacuum, vacuum leak detection should be carried out, re-vacuum.
4.管道阀门液体流动不畅或堵塞 pipeline valve fluid flow or blocked
可能是液体二氧化碳形成干冰的原因造成,应停止使用,用热空气加温管阀至畅通为止。May be caused by the formation of dry ice, should stop using, with hot air heating pipe valve until smooth.