1.储罐的使用与维护,应按“压力容器安全技术监察规程”要求和本说明进行。
The use and maintenance of the storage tank shall be carried out according to the requirements of the Pressure Vessel Safety Technical Supervision Regulations and these instructions
2.日常检查与维护 Daily inspection and maintenance
储罐在运行过程中,要经常检查安全阀、压力表、液位计工作是否正常,阀门管路是否有泄漏,外部有无异常现象,发现问题及时处理。
During operation of the tank, check the safety valve, pressure gauge and liquid level meter regularly, whether the valve line is leaking, whether there is any abnormal phenomenon outside, and find the problem to be handled in time.
3.定期校验 Regular verification
3.1安全阀整定压力不大于2.27Mpa,每年至少校验一次,并加铅封,作好记录。
Safety valve setting pressure is not more than 2.27Mpa, at least once a year, and add seals, make a record.
3.2定期检查夹层真空度,未装低温介质的情况下真空度应低于65Pa,装有低温介质的情况下,真空度应低于10Pa为合格。
Regularly check the sandwich vacuum, the vacuum should be less then 65Pa without vacuum medium; with a low temperature medium, the vacuum should be less than 10Pa for the pass.
【产品详情图片】
【标题】
液体的排放 liquid discharge
【产品详情图片】
2.4.1液体二氧化碳的正常排放是在储罐增压后,开启V2排液阀,V3回气阀,液体二氧化碳便流入汽化器汽化,供使用点使用。
The normal discharge of liquid carbon dioxide is after pressurization of the tank, open the V2 drain valve, V3 return valve, the liquid carbon dioxide will flow into the vaporizer vaporization for use point.
2.4.2为满足排液过程的稳定压力,应按“储罐的增压”操作方法进行增压。
In order to meet the steady pressure of the drainage process, it should be pressurized according to the method of "pressurized tank".
【产品详情图片】
【标题】
注意事项matters need attention
在您购买我公司的设备之际,请接收我们诚挚的谢意。我们严格按标准和工艺进行制造,但由于安装和使用的不当,仍会引起意外事故。本使用说明书所示安全事项是为了您能安全正确的使用本设备,防止您或他人的危害或损害于未然,一旦实施错误的操作方法,其产生的后果均与安全有关。请接受本使用说明书的指导,并注意如下事项:
Please receive our sincere thanks for your purchase of our equipments. We manufacture in strict accordance with standards and craftsmanship, but will still cause accidents due to improper installation and use. The safety instructions in this manual are for the purpose of safe and correct use of this equipment, to prevent the harm to you or others from harm or damage, and once the wrong operation method is implemented, all the consequences arising therefrom are safety related. Please accept the instructions in this manual, and note the following:
1本设备属于特种设备,要设专职人员管理与操作,操作人员要经过培训持证上岗,否则由于误操作和使用,会造成危及生命安全的可能。
The equipment belongs to special equipment, which should be managed and operated by full-time personnel. Operators should be trained and certified to be on duty. Otherwise, it will be possible to endanger life safety due to misoperation and use.
2 本设备的安装、使用及维修应符合JB6898-1997《低温液体贮运设备 使用安全规则》的规定。本设备应放在室外、通风良好的场所。CO2有很强的窒息性,会引起窒息危险,甚至危及生命。
the installation, use and maintenance of the equipment shall conform to the provisions of JB6898-1997 "safe rules for the use of cryogenic liquid storage and transportation equipment". The equipment should be placed outdoors and well ventilated. CO2 has a strong asphyxiation, which can cause choking hazards and even life.
3 本设备贮存的是-40℃的低温液体,管道、阀门冻结堵塞时严禁用重物敲击、火烤或冷水喷淋等方法解冻,应用70~80℃干净无油的热空气、热氮气解冻。
this equipment is to 40 ℃ cryogenic liquid storage, pipe, valves, frozen jams it is forbidden to use heavy percussion, fire, or cold water spray method of thawing, application of 70 ~ 80 ℃ clean hot air, hot nitrogen release without oil.
【产品详情图片】
【变量3】【变量2】【变量1】
二氧化碳储罐材料
绝热性能
绝热材料选用热态下的珠光砂充填夹层并抽真空,夹层封结后真空度标准为:
有效容积:小于等于 10m 3 真空度≤ 2Pa ,大于 10m 3 小于等于 50m 3真空度≤ 3Pa ,大于 50m 3 小于等于 100m 3 真空度≤ 5Pa ,以精湛的技术,独特的填充工艺,质量保证承诺,以达到的绝热效果。
安全技术特性
低温液体二氧化碳储罐采用 “组合、安全系统阀”使用两组安全阀同时工作,在安全阀定期校验时可关闭一侧,另一侧继续工作,确保储罐的安全运行。
操作系统
储罐内容器上部设置了压力表,差压式液位计和液位对照表,可以随时掌握内容器储存量及压力变化,便于充装及排液时的操作。
检测系统
储罐下部设置了储罐真空检测、真空规管及真空阀可定期或随时用真空计进行检测夹层真空度,确保储罐的安全运行。